Hotline
86+0731-58534888,86+13607322318
Introduction
The instrument uses the Hot Disk method, based on TPS technology, using a Hot Disk probe。advantage:
1.Directly measuring heat propagation can save a lot of time;
2.Will not be affected by contact thermal resistance like static method;
3.No special sample preparation is required, only a relatively flat sample surface is required for solid materials. Different types of materials adopt different testing schemes and computational mathematical models, which have advantages such as fast measurement speed, wide applicability, and the ability to successfully avoid the influence of natural convection during the experimental process. The advantages of wide range of actual testing materials, wide range of thermal conductivity, simple sample processing, and fast testing speed are currently popular testing methods.
Equipment reference standards:ISO 22007-2:2008, GB/T32064-2015.
Test materials: thermal conductivity coefficient, thermal conductivity coefficient (thermal diffusion coefficient), specific heat capacity, thermal storage coefficient and thermal resistance of solid, powder, liquid, paste, coating, film, thermal insulation material, thermal insulation material, anisotropic materials, such as metal, alloy, graphite, thermal conductive silicone grease, silica gel, silicone rubber, ceramics, rock, polymer, paper, fabric, foamed plastic, concrete, composite plate, paper honeycomb plate, etc.
Main parameters
1.Thermal conductivity test range:0.001~500 w/(m.k),Resolution is 0.0001w/(m.k);
2.Range of thermal diffusion coefficient (thermal conductivity coefficient):0.1~100 m2/s;
3.Range of heat storage coefficient:0.1~30 w/(m2.k);
4.Specific heat capacity range:0.1~5 kJ/(kg.℃);
5.Thermal resistance range:0.5~0.000005 mm2.k/w;
6.Temperature measurement accuracy:≤0.0001℃;
7.Measurement relative error:≤3%;
8.Repeatability error:≤ 3%;
9.Test time:1~120s.
10.Test ambient temperature range:-40~150℃;Standard configuration: Room temperature.
Various high and low temperature control boxes (-40~150 ℃) or test conditions under vacuum can be selected according to customer requirements. The contract stipulates that the cost will be calculated separately.
11.Probe configuration:Standard configuration: diameter Φ 15mm.
Probe diameter can be selected according to customer requirements: Φ 30mm, Φ 15mm, Φ 7.5mm, Φ 4mm or at the same time, as agreed in the contract, the cost will be calculated separately.
12. Various types of samples:
12.1.Solid block or circular, square, or irregular samples do not require special preparation, only a relatively flat sample surface equipped with a dedicated sample clamping device.
12.2.There are no special requirements for powder, paste, or liquid substances, and a dedicated sample testing box is provided.
12.3.The thinner material (thickness 0.01-1mm) was tested using a dedicated testing plan and mathematical model.
12.4.High thermal conductivity materials (100-500W) are tested using a dedicated testing plan and mathematical model.
12.5.Thermal insulation materials (0.010-0.050W) shall be tested using a dedicated testing plan and mathematical model.
13.Using fully automated testing software, quickly and accurately analyze the experimental process parameters of the samples and output reports.
14.Power:AC 220V±10%,50/60 Hz, <500w.
Complete set
1.One mainframe;
2.Analysis software package (Chinese and English versions);
3.A computer in Lenovo (optional);
4.Two pieces of standard sample;
5.A set of random accessories (One set of grease, paste, and powder test boxes, and one set of test racks each).
Size and weight
Host:(Length × width × height) 400×450×450mm, NET weight: 20Kg.
service
Free one-year warranty, long-term technical services, and lifetime free software upgrades.
The last product: SJY Material high temperature character measure instrument
The next product: DRE-V Multifunction Rapid Thermal Conductivity Tester ( HotDisk)