国产精品亚洲色婷婷99久久精品,人妻丰满熟妇AV无码区动漫 ,亚洲熟女综合一区二区三区,成人香蕉视频网站

The current position:Home > Products > thermal conductivity tester > DRL-III Thermal Conductivity Tester(Heat flux) (Upgrade)

Click to enlarge

DRL-III Thermal Conductivity Tester(Heat flux) (Upgrade)

RELATED ARTICLES
Introduction

DRL-III Thermal Conductivity Tester(Heat flux)  (Upgrade)

Introduction

It is mainly used to measure the thermal resistance of thin thermal conductor, solid electrical insulating material, thermal conductive silicone, resin, rubber, beryllium oxide ceramic, alumina ceramic, contact thermal resistance at solid interface and thermal conductivity of materials. The detection material is solid sheet, and the frame can detect powder state material and paste material。 Reference Standards for instruments:MIL-I-49456AInsulation sheet, thermal conductive resin, thermal conductive glass fiber reinforcement;GB/T 5598-2015Method for determination of thermal conductivity of beryllium oxide ceramics;GB/T 29313—2017 Test methods for thermal conductivity of electrical insulating materials;ASTM D5470-2017Standard Test Method for Thermal Transmission Properties of Thermally Conductive Electrical Insulation Materials。

   DRL-III thermal conductivity instrument is designed and manufactured according to ASTM D5470-2017 standard. Our company has accumulated more than 10 years of production, manufacturing, user experience, so that product performance is constantly improving and mature. Servo motor is used to control precise automatic pressure, automatic thickness measuring device, and connected with computer to achieve full automatic control. The instrument adopts 6-point temperature gradient detection, which improves the testing precision. The thermal protection device is added around the test rod in the test head to reduce the influence of environmental temperature on the test. The thermal resistance curve can be measured at different pressures, and the thermal conductivity, thermal resistance and contact thermal resistance at the interface can be measured by using the optimized mathematical model. Adopt the latest technology cold end temperature automatic compensation.

Main parameters

1、Sample size:Φ30mm(Standard configuration),Other sizes can be customized;

2、Sample thickness: 0.001~50mm(Standard configuration),Typical thickness:0.02~20mm;

3、Hot Meter Bar temperature control range:Rt100℃(Standard configuration),Rt299.99,Rt500℃,Temperature control accuracy0.01℃;

4、Cold Meter Bar temperature control range099.00,Temperature control accuracy0.01℃

5、Thermal conductivity test range0.0150W/m.k, 0.1300W/m.k,The computer software switches the range automatically;

6、Thermal resistance test range0.050.000005m2.K/W
7、Pressure measurement range01000N, Servo motor control, can accurately set the pressure holding value, control accuracy: 0.1N

8、Measuring range of thickness:0~50.00mm,Precision1um,Automatic thickness measurement;

9、Number of samples  1。

10、Test accuracy:Better than3%;
11、Experimental methods: thermal resistance test, thermal conductivity test, contact thermal resistance test, aging reliability test, material compression performance test, contact thermal resistance test.

12、Computer automatic test, and the realization of data printing output;

13、Power 220V/50Hz;500W.

Typical test materials

1、Metallic materials;          

2、Heat-conducting silicone grease;    

3、Thermal conductive silicone pad;       

4、Thermal conductive engineering plastics;

5、Heat conductive tape (the sample is very thin and sticky, it is difficult to make a regular single sample, with transparent plastic on one side and paper on the other);

6、Aluminum substrate, copper clad laminate;          

7、Quartz glass, composite ceramics; 

8、Foam copper, graphite paper, graphite sheets and other new materials。

Complete set

1、One mainframe;

2、Analysis software package (Chinese and English versions);

3、HX-1005 precision cryostat water tank (temperature control accuracy 0.01 ° C);

4、A computer in Lenovo (optional);

5、Two pieces of standard sample;

6、A set of random accessories (grease, paste, powder test box, sampling convenient sheet forming stamping die each set)。

Size and weight

1、Host: Standard Landing Machine:(Length × width × height) 550×450×1550mm, NET weight:100Kg,   

Small desktop models:(Length × width × height) 500×400×780mm,   NET weight: 60Kg;   

2、Precision cryostat sink: (Length × width × height) 300×350×530mm,  NET weight:35Kg 。

 

 

 

 

Order

留言框

  • Theme:

  • Content:

  • Commpany:

  • Name:

  • Telephone:

  • Email:

  • Address:

  • Province:

  • Verification Code:

Contact

Email:130732189@qq.com
Address:Add:No.168 Xiaotang east road,German Industrial Park,Xiangtan City,Hunan,China